Market-leading sensing technology combined with a unique desiccant head assembly ensures unparalleled speed of response. As a result, the SADPmini2-L offers exceptional sensitivity, accurate to ±2 °C (±3.6 °F) dewpoint — and fast, consistent operation with minimal air/gas usage.
The SADPmini2-L is designed for ease of use and reliability in demanding environments, with a full-colour LCD display showing multiple engineering units simultaneously, along with real-time graphing and screenshot features and advanced data logging and connectivity to accurately record and store trace moisture measurement data for later analysis.
- Highly customised solutions
- Trusted by industry leaders
- Distributors worldwide
- Over 30 years experience
Log moisture measurements in the field
Key features
- Robust, lightweight and portable, for efficient spot checks without operational downtime
- Ultra high-capacitance aluminium oxide sensor coupled with our unique desiccant head assembly for rapid and accurate trace moisture measurements, minimising gas usage
- AutoCal span correction function to ensure optimum accuracy between laboratory calibrations
- Select from °C or °F dewpoint, and absolute values in ppm(V), ppm(w), mg/m³, or lb/MMSCF
- Bluetooth and USB connectivity for immediate data analysis and archiving via a dedicated Android/iOS mobile app or PC
- Capable of storing over 300,000 data points, with real-time graphing and quick log features for enhanced data analysis
- Easy to use, view and set user preferences and languages. Supports English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese and Korean
- Designed for use in the toughest environments
Technical Data
General | |
Sensor/Transmitter Type | Sensor |
User Interface | Ten languages: English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese & Korean |
Accessories | 2m PTFE sampling hose, pipe fittings, battery charger and cable, carrying strap, pressure dewpoint calculator |
Documentation | Instruction manual, calibration certificate |
Sensor | |
Sensing Element | Ultra-high capacitance aluminium oxide |
Dewpoint Range | Overall range offered between -110 °C to +20 °C (-166 °F to +68 °F) dewpoint. -110 °C to -20 °C (-166 °F to -4 °F) dewpoint -100 °C to 0 °C (-148 °F to +32 °F) dewpoint -80 °C to +20 °C (-112 °F to +68 °F) dewpoint |
Approvals | CE, UKCA |
Automatic Calibration | Span check and correction performed by following simple on-screen instructions. |
Accuracy | ± 2 °C (±3.6 °F) dewpoint |
Sensor Calibration | Supplied with a calibration certificate traceable to National and International Humidity standards at NPL. |
Pressure Correction | Integral calculator to display pressure dewpoints. Gauge pressure can be entered in kPa, kg/cm², bar or psi. |
Temperature Coefficient | Temperature compensated for operating range |
Response Times | Dry to wet: -100 °C to -20 °C (-148 °F to -4 °F) - Instantaneous; in less than 5 seconds Wet to dry: 0 °C to -60 °C (14 °F to -76 °F) - less than 120 seconds |
Repeatability | Better than ±0.3 °C dewpoint |
Sample Flow Rate | Flow independent, ideally 5 - 15 L/min. Max 20 L/min |
Calibration Warranty | 12months from date of dispatch |
Electrical | |
Electromagnetic Compatibility (EMC) | Complies with BS EN IEC 61326-1 |
Display | Full colour LCD graphical display with backlight, 240 x 320 resolution. |
Display Dimensions | 3.5 inch |
Power Supply | Rechargeable Li-ion battery (3.65 V nominal). |
Battery Life | Excess of 150 hours |
Charging Time | Approximately 14 hours |
Charging | Universal mains charger via USB port |
Resolution | 0.1 °C, 0.1 °F dewpoint or 0.1 ppm(V) |
Repeatability | Better than ±0.2 °C dewpoint |
Warm Up Time | 2 seconds |
Engineering Units | °C, °F, ppm(V), ppm(w), g/m³, lb/MMSCF |
Communications | Bluetooth connectivity via the app on a tablet/smartphone or PC/laptop (running Windows®) USB connectivity to PC/laptop running Windows®. |
Measurement Samples | Sample data including dewpoint, pressure-compensated dewpoint, pressure and temperature data displayed in table format. |
System requirement | PC/Laptop running any version of Windows®, 32 or 64-bit |
Mechanical | |
Dimensions in mm (H x W x D) | 215 x 108 x 124 |
Weight | 1.4 kg |
Operating Pressure | Atmospheric pressure. Maximum 0.3 bar/4 psi |
Operating Humidity (External) | Maximum 95% Non-Condensing |
Operating Temperature | -20°C to +50°C (-4°F to +122°F) |
Storage Temperature | -20 °C to +50 °C Maximum 95% Non-Condensing |
Sensor Protection | 316 sintered stainless steel filter - 50 micron |
Weatherproof Classification | IP66 / NEMA 4X |
Fittings | Fir tree fitting, 0.25” (¼”), 6 mm, 0.125” (⅛”) - SS compression fitting |
Mechanical Warranty | 12 months in case of defective parts or faulty workmanship. |
Data | |
Logging Software | User Tool |
Data Logging | 300,000 readings. Date and time stamped data. Log directly to PC when connected via USB or wirelessly via Bluetooth. |
Data Location | 20 separate Location IDs can be entered (alpha-numerical) for data collection at pre-programmed locations |
Sampling Rates | User-selectable logging intervals from five seconds to one hour and real-time data logging in graphical formats. |
Data Display | Graphical and numerical |
Real Time Recording | Programmed to monitor, record and graphically present data in real time directly to a PC/laptop. |